Specify a checker mode to be used for current and resistance estimation. The checker modes that are available in interactive SDR are as follows:
- Enforce
Estimates the current in the edited wire and vias and automatically calculates the wire width to avoid EM or maximum resistance violations.
- Notify
Estimates the current in the edited wire using a color coding based on EAD EM violations color settings.
- Off
Does not update the wire width and there is no feedback on the estimated current or resistance.