Product Documentation
Setup Library Task Assistant
Product Version IC23.1, November 2022

Known Problems and Solutions

This document describes the known issues with the Setup Library assistant and suggests the workarounds for these issues. Each issue is identified by a Cadence Change Request (CCR) number.

CCR 1986378: The Calculate Coverage icon on the toolbar is displayed with an exclamation mark even if no SPACE is defined in the verifier view.

Description: Currently, the Calculate Coverage command on the ADE Verifier toolbar is diaplays an exclamation mark for any changes in the ADE Verifier setup even if the current setup does not use a Verification Space.

Solution: Currently, there is no workaround.


CCR 1986378: All referenced corners show bold if Corners Setup is opened and closed without any modification.

Description: Open a maestro cellview containing multiple corners and a  valid corner setup in the Setup Library. Drag the Corners Setup from the Setup Library to the Data View to create a reference. In the Data View, choose 'Open Corner Setup' from the context menu. Without making any change, close the Corners Setup by clicking OK. All the referenced corners (or corner names) in the Data View are shown in bold format but their values do not change, or their values are  the same as the referenced corners. 

 This issue occurs when one of the corners in the Corners Setup contains the model file information, but other corners do not have any model file information. When these corners are opened with the Corner Setup form, the SDB structure for these corners is modified to include the model file information, even when the model is not included in the corner definitions. 


Solution: Currently, there is no workaround.

See Also:

What's New




 ⠀