Product Documentation
Virtuoso Automated Chip Assembly Routing Flow Guide
Product Version IC23.1, October 2023

Shield Process Rule Override Editor Form

To open the Shield Process Rule Override Editor form, double-click a field in the Shield column on the Nets tab. Alternatively, double-click a field in the Shield column on the Shield tab.

The Shield Process Rule Override Editor form has the following components.

Toolbar

Lets you copy and delete a constraint.

Fields

Lets you specify the options for shield constraints.

Toolbar

The following table lists the functions of the different buttons on the Shield CG Editor form toolbar.

Icon Command Description

Copy Constraint Group

Lets you copy the constraint group.

Delete Constraint Group

Lets you delete the constraint group.

Fields

The Shield Process Rule Override Editor form lets you specify the options for Shielding constraints. The form contains the following fields.

Field Description

Shield Group Name

Lets you select a pre-existing shielding constraint.

Shield Type

Lets you specify the type of shield to create for the given signal nets. The shielding types are: None, Parallel, Tandem, and Coaxial.

  • None No shield.
  • Parallel Planar shield wires parallel to the signal wire.
  • Coaxial Both tandem and parallel shields to surround the signal wire on four sides.
  • Tandem Shield wires on a given layer above and below the signal wire.

Shield Enclosure

Lets you select the enclosure type to add shield wires all around vias in the preferred direction. The shield enclosures are: None, Center, Half, and Full. The default is Half.

Group Shield Type

Lets you select a group shielding type. The group shielding types are Surround and Interleaved.

Tolerance

Lets you specify absolute tolerance when matching shield lengths.

Valid Shield Layers

Lets you select the layers to prevent shields from being added on the selected layers.

Shield Width/Space

Toggles to display the width and spacing layer table.

Layer

Displays the name of the layer.

Min W

Lets you specify the minimum width to be used for the layer.

Min S

Lets you specify the minimum spacing to be used for the layer.

Advanced Shield

Share Shields

Lets you select whether or not shield routes can be shared by nets.

Use Existing Shapes

Lets you select whether or not to use the existing shapes.

Shield Terminal

Lets you select whether or not shield terminals should be connected.

Shield Minimum Length

Specifies whether or not to prevent shielding of any signal wire that is shorter than the given length.

Tie Shield

Specifies whether ties should be added to tie the new shield wires to the shield nets they belong to.

Frequency

Specifies the maximum distance between ties that must be inserted to tie the new shield wires to their respective shield nets.

Shield Redundant Via

Adds redundant vias to tie shield wires to shield nets at each location where the shield wires overlap their respective existing power and ground rails.

Shield Via #Cuts

The minimum cuts constraint for each cut layer matching a valid via for the shielding wires.

Related Topics

Opening Routing Constraint Manager

Virtuoso Routing Constraint Manager

Routing Constraint Manager User Interface


Return to top
 ⠀