Shield Process Rule Override Editor Form
To open the Shield Process Rule Override Editor form, double-click a field in the Shield column on the Nets tab. Alternatively, double-click a field in the Shield column on the Shield tab.
The Shield Process Rule Override Editor form has the following components.
|
Toolbar
|
Lets you copy and delete a constraint.
|
|
Fields
|
Lets you specify the options for shield constraints.
|
Toolbar
The following table lists the functions of the different buttons on the Shield CG Editor form toolbar.
|
Icon
|
Command
|
Description
|
|

|
Copy Constraint Group
|
Lets you copy the constraint group.
|
|

|
Delete Constraint Group
|
Lets you delete the constraint group.
|
Fields
The Shield Process Rule Override Editor form lets you specify the options for Shielding constraints. The form contains the following fields.
|
Field
|
Description
|
|
Shield Group Name
|
Lets you select a pre-existing shielding constraint.
|
|
Shield Type
|
Lets you specify the type of shield to create for the given signal nets. The shielding types are: None, Parallel, Tandem, and Coaxial.
-
None No shield.
-
Parallel Planar shield wires parallel to the signal wire.
-
Coaxial Both tandem and parallel shields to surround the signal wire on four sides.
-
Tandem Shield wires on a given layer above and below the signal wire.
|
|
Shield Enclosure
|
Lets you select the enclosure type to add shield wires all around vias in the preferred direction. The shield enclosures are: None, Center, Half, and Full. The default is Half.
|
|
Group Shield Type
|
Lets you select a group shielding type. The group shielding types are Surround and Interleaved.
|
|
Tolerance
|
Lets you specify absolute tolerance when matching shield lengths.
|
|
Valid Shield Layers
|
Lets you select the layers to prevent shields from being added on the selected layers.
|
|
Shield Width/Space
|
Toggles to display the width and spacing layer table.
|
|
Layer
|
Displays the name of the layer.
|
|
Min W
|
Lets you specify the minimum width to be used for the layer.
|
|
Min S
|
Lets you specify the minimum spacing to be used for the layer.
|
|
Advanced Shield
|
|
|
Share Shields
|
Lets you select whether or not shield routes can be shared by nets.
|
|
Use Existing Shapes
|
Lets you select whether or not to use the existing shapes.
|
|
Shield Terminal
|
Lets you select whether or not shield terminals should be connected.
|
|
Shield Minimum Length
|
Specifies whether or not to prevent shielding of any signal wire that is shorter than the given length.
|
|
Tie Shield
|
Specifies whether ties should be added to tie the new shield wires to the shield nets they belong to.
|
|
Frequency
|
Specifies the maximum distance between ties that must be inserted to tie the new shield wires to their respective shield nets.
|
|
Shield Redundant Via
|
Adds redundant vias to tie shield wires to shield nets at each location where the shield wires overlap their respective existing power and ground rails.
|
|
Shield Via #Cuts
|
The minimum cuts constraint for each cut layer matching a valid via for the shielding wires.
|
Related Topics
Opening Routing Constraint Manager
Virtuoso Routing Constraint Manager
Routing Constraint Manager User Interface
Return to top