stackDummyFingerCount

APR.device.fill stackDummyFingerCount int int_spacing

Description

Specifies the number of fingers to be included as stack dummy transition fill when they are inserted in the Fill step of the automated device placement flow.

The default value is 2.

This environment variable is valid only in certain advanced node PDKs.

GUI Equivalent

None

Examples

envGetVal("APR.device.place" "stackDummyFingerCount")
envSetVal("APR.device.place" "stackDummyFingerCount" 'int 3)