Via Clustering Settings Form
Use the Via Clustering Settings form to configure options for via clustering. Via clustering requires the maximum spacing and maximum number of cuts for each via layer.
|
Field
|
Description
|
|
Cut Layer
|
Specifies the names of via layers found in the layout
|
|
Max Spacing
|
Specifies the spacing (in microns) between cuts. Any cuts that are within the given spacing are considered for clustering. Set this value to greater than or equal to cut spacing to cluster the vias on a layer.
|
|
Max Cuts
|
Specifies the maximum array size for a cluster. For example, a value of 50 would create a single shape up to a 50 x 50 array. This is typically set to a large number so that all cuts in a via are clustered.
|
Related Topics
Configuring Settings for Electromagnetic Simulations
Running an EMX Simulation (IC Layouts Only)
Running a Simulation using Clarity 3D Solver
Specifying Options for Via Clustering
Saving Default Parameters for Via Clustering
Return to top