Dynamic Excessive Element Current Check (dyn_exi)
Description
Reports elements and devices carrying currents (absolute value) higher than the current threshold (ith) for a time longer than the duration threshold (duration).
The results are written to the dynamic.xml file, which can be viewed in a Web browser.
Syntax
Name dyn_exi parameter=value ...
Parameters
Design check parameters
|
dev
|
[...]
|
The instance names of device or elements to be checked.
|
|
ith
|
(ampere)
|
Current threshold. Default is none.
|
|
duration
|
5.00E-09 sec
|
Duration threshold. Default is 5.00E-09 sec.
|
Filtering parameters
|
time_window
|
[tstart, tstop] sec
|
The time window during which the circuit check is applied. Multiple non-overlapping time windows are supported. Default time window is 0 to tend.
|
|
error_limit
|
10000
|
Maximum number of errors reported. Default is 10000.
|
Wildcard scoping
|
inst
|
[...]
|
Subcircuit instances to which the check is applied. Default includes all instances (inst=*).
|
|
xinst
|
[...]
|
Subcircuit instances to be excluded from the check. Default is none.
|
|
subckt
|
[...]
|
The instances of the specified subcircuit to which the check is applied. Default includes all subcircuits (subckt=*).
|
|
xsubckt
|
[...]
|
The instances of the specified subcircuits that are excluded from the check. Default is none.
|
|
depth
|
8
|
Hierarchy levels (starting from top, instance, or subcircuit scope) to be checked. Default is 8.
|
Related Topics
Dynamic Excessive Element Current Check